Governor Model: WSHYGP

 

Model Equations and/or Block Diagrams

   

Parameters:

Trate Turbine rating, MW
db1pu Intentional deadband width, pu
Err Intentional db hysteresis, pu
Td Input filter time constant, sec
Ki Integral gain, pu
Tf Filter time constant, sec
Kd Derivative gain, pu
Kp Proportional gain, pu
R Permanent droop, pu
Tt Power feedback time constant, sec
Kg Gate servo gain, pu
Tp Lead time constant, sec
Velopen Maximum gate opening velocity, pu/sec
Velclose Maximum gate closing velocity, pu/sec
Pmax Maximum gate opening, pu of mwcap
Pmin Minimum gate opening, pu of mwcap
db2pu Unintentional deadband, pu
Gv1 Nonlinear gain point 1, pu gv
Pgv1 Nonlinear gain point 1, pu power
Gv2 Nonlinear gain point 2, pu gv
Pgv2 Nonlinear gain point 2, pu power
Gv3 Nonlinear gain point 3, pu gv
Pgv3 Nonlinear gain point 3, pu power
Gv4 Nonlinear gain point 4, pu gv
Pgv4 Nonlinear gain point 4, pu power
Gv5 Nonlinear gain point 5, pu gv
Pgv5 Nonlinear gain point 5, pu power
Aturb Turbine numerator multiplier
Bturb Turbine denominator multiplier
Tturb Turbine time constant, sec